2020 Volume 76 Issue 2 Pages I_594-I_599
To corrosion protection in marine steel structures, cathodic protection methods is applied to the under-seawater area, and coating protection methods is applied above the tidal zone. Therefore, we considered to expand the effective range of cathodic protection in under-seawater to the coating protection area by apply high-conductivity mortar mixed with carbon as a coating material. Compared to ordinary concrete, it can reduce the resistance to 1/100 and confirmed that it can be protected with 0.1 µA/cm2 corrosion protection current in underwater environment and 20 µA/cm2 in dry environment. At the time of two years of exposure, sufficient anticorrosion performance was confirmed at a depth of L.W.L+160 cm or less.