Journal of Japan Society of Civil Engineers, Ser. B3 (Ocean Engineering)
Online ISSN : 2185-4688
ISSN-L : 2185-4688
Annual Journal of Civil Engineering in the Ocean Vol.37
SEISMIC BEHAVIOR OF THE CONNECTING STRUCTURE IN HANEDA AIRPORT D-RUNWAY DURING THE 2011 OFF THE PACIFIC COAST OF TOHOKU EARTHQUAKE AND ITS REPONSE ANALYSIS USING FLIP
Yuji NIIHARAShintaro OhnoTakaaki KOBAYASHIKenichi HIRASASoichi TASHIROKeiji KOZAWATakatoshi NOGUCHIAtsushi NOZU
Author information
JOURNAL FREE ACCESS

2021 Volume 77 Issue 2 Pages I_379-I_384

Details
Abstract

 On March 11, 2011, the 2011 off the Pacific coast of Tohoku Earthquake occurred and strong motion records were obtained on the D-Runway of Haneda Airport. The behavior of the D-Runway during the earthquake was investigated using the observation records and the validity of its seismic design was verified. FLIP simulation was performed using the model and parameters used for the design of the connecting structure between the landfill and pier sections by inputting the observed ground acceleration. As a result, the response of the landfill and the pier simulated by FLIP were in good agreement with the observed records. Regarding the connection structure, although the lateral displacement obtained by FLIP exceeded the observed value, it was confirmed that the seismic design using FLIP resulted in a conservative design.

Content from these authors
© 2021 Japan Society of Civil Engineers
Previous article Next article
feedback
Top