Journal of Japan Society of Civil Engineers, Ser. A1 (Structural Engineering & Earthquake Engineering (SE/EE))
Online ISSN : 2185-4653
ISSN-L : 2185-4653
JSCE Journal of Hybrid Structures, Vol.1 (Paper)
SHEAR CAPACITY AND SHEAR FORCE - SLIP RELATIONSHIP OF HEADED STUD CONNECTORS UNDER CONTROLLED SHEAR AND AXIAL COMPRESSIVE FORCES
Yohei TAIRATadatomo WATANABEShigehiko SAITOYoshihisa MIZOEHiroshi SHIMAAkinori NAKAJIMA
Author information
JOURNAL FREE ACCESS

2014 Volume 70 Issue 5 Pages II_69-II_80

Details
Abstract
 If the axial compressive force as well as the shear force is applied to the interface between flanges of the steel beam and the concrete which is connected by headed studs, shear force or shear force-slip relationships is different from the case where the axial force is not applied is the obvious. In this study, push-out tests of headed studs are conducted with axial compressive force controlled by using hydraulic jacks, and shear capacity and shear force-slip relationships of such studs under both shear force and axial compressive force are investigated. And, the shear capacity formula which is used the coefficient that take into account the influence of axial compressive force is proposed.
Content from these authors
© 2014 by Japan Society of Civil Engineers