Abstract
For the joints with zinc-aluminum alloys sprayed surfaces, hot-dip galvanized bolts are applied and such bolts are tightened by turn-of-nut method. However, it is unclear how much axial force is induced into the bolts in the joints with this metal-sprayed surfaces. In order to examine slip coefficient of the bolted joints with zinc-aluminum alloys-sprayed contact surfaces slip tests of high strength bolted joints were carried out. On the basis of above examinations, the slip coefficient with this metal-sprayed surfaces is proposed in this paper. To clarify the induced axial force of the bolts, bolt-tightening tests were carried out. Considering bolt diameter, bolt length, induced axial forces and their relaxation, nut rotation angles are proposed in relation to different bolt size.