Journal of Japan Society of Civil Engineers, Ser. F2 (Underground Space Research)
Online ISSN : 2185-6583
ISSN-L : 2185-6583
Paper (In Japanese)
EFFECTIVENESS OF SMOKE EXTRACTION DURING A TUNNEL FIRE IN SHORT ROAD TUNNELS
Yasuhiro MIKAMENobuyoshi KAWABATAMiho SEIKE
Author information
JOURNAL FREE ACCESS

2015 Volume 71 Issue 1 Pages 11-19

Details
Abstract
 The present paper indicates that effects of smoke extraction by ventilation system in road tunnel fires, which model tunnels adopted urban U-shaped tunnels shorter than 500 m length. The investigation used smoke CFD simulation and evacuation simulation. In the case with natural ventilation velocity 1.2 m/s, the situation where it difficult for over 10 users to evacuate due to exposure by smoke occurred with no smoke extraction by ventilation facilities. Meanwhile in the case with over 0.3 m3/s·m of smoke extraction by ventilation facilities, smoke propagation can be controlled even with natural ventilation existing, the number of users exposed by smoke decreased from 3 persons to 0. Hence, it was confirmed that even in short tunnels smoke extraction by ventilation facilities was necessary to keep the users' evacuation safety in tunnel fires.
Content from these authors
© 2015 Japan Society of Civil Engineers
Previous article Next article
feedback
Top