Environmental Infections
Online ISSN : 1884-2429
Print ISSN : 0918-3337
ISSN-L : 0918-3337
Effect of Group Guidance for Fitting N95 Filtering Facepiece Respirators
Yuzuru OGAWAMayumi YOKOOKAReika ISHIZUMIYoko SAITO
Author information
JOURNAL FREE ACCESS

2006 Volume 21 Issue 2 Pages 91-95

Details
Abstract
Training by the fit test and fit check are essential to use the N95 Filtering Facepiece Respirator. A survey of N95 respirator fitting with no guidance and group guidance including fit check and fit test was carried out to assess the importance of training. As a result, 48 of 79 health care workers working at “S” hospital could not fit the N95 respirator correctly. These health-care workers were divided into a guidance group and no guidance group. N95 respirator fitting was better in the guidance group (p<0.05), indicating the importance of training and the effectiveness of group guidance. However, 36% of the guidance group could not successfully fit the respirator. These health care workers need individual guidance and workers who cannot fit the N95 respirator should be provided with another type of respirator.
Content from these authors
© Japanese Society of Environmental Infections
Previous article Next article
feedback
Top