Journal of Japan Solar Energy Society
Online ISSN : 2433-5592
Print ISSN : 0388-9564
Research paper
A Proposal for Equivalent Circuit Between PV Module/String and the Ground(2)
- An improvement on high-frequency components and data analysis under the outdoor condition -
Kazuhiko KATO
Author information
JOURNAL FREE ACCESS

2024 Volume 50 Issue 2 Pages 67-73

Details
Abstract

In the previous paper, author has proposed an equivalent circuit between PV module/string and the ground which consists of one resistance and multiple RC-components, and it was also described that at least two of them had higher attenuation frequency than 1Hz. In this paper, some new results obtained from further experiments and discussion are shown as follows: four RC-components which had high attenuation frequency were found, i.e. ≈50kHz, ≈103Hz, ≈102Hz, ≈101Hz, respectively. Under rain condition, on the other hand, their attenuation frequencies and resistances decreased and their capacitance increased very much. These four RC-components affect risk of electrical shock. A preliminary-stage discussion on the electrical shock, which was based on the estimates of the RC-components obtained under both no-rain and rain conditions, pointed out that the risk of electrical shock drastically increase under rain condition.

Content from these authors
© Japan Solar Energy Society
Previous article Next article
feedback
Top