Development of the Haptic Device using Linear Oscillatory Actuators
Takashi SuzukiKazushige Magatani
Author information
JOURNAL FREE ACCESS

2016 Volume 54Annual Issue 28PM-Abstract Pages S336

Details
Abstract

The objective of this study is the development of the device gives direction of power for the human. The device made up of 4 stack linear oscillatory actuators on 3 axis. These actuators are mounted on the ball-like metallic frame that is 40 mm diameter. We can feel the direction of power using this device. Displayed angles transform Spherical Polar Coordinates. The microprocessor makes PWM based on Spherical Polar Coordinates. PWM signals drive 12 actuators. In the future, it will be possible to guide the visually-impaired in arbitrary direction.