Operation of high-efficiency waste to energy plant -Investigation of boiler tubes corrosion under higher steam condition-
*shintaro nakaharahiroshi sunadakatsuyoshi tanidahiroyuki hosodatakeo miyamura
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract

Higher efficiency in waste to energy plants, as decentralized power suppliers, has been required. A waste to energy plant, Hatsukaichi energy clean center, has been operated with 450 C× 6MPa boiler and heat supplying to a local industry since April 2019. This plant was designed based on our previous corrosion test of SUS310S tubes. In this study, corrosion speed of super-heated tubes after 19 months and energy efficiency are reported.