Bulletin of JSME
Online ISSN : 1881-1426
Print ISSN : 0021-3764
Torque Performance of Pressure Balanced Type Vane Motor at Start and in Low Speed Range
Akira HIBITsuneo ICHIKAWA
Author information
JOURNAL FREE ACCESS

1976 Volume 19 Issue 138 Pages 1490-1496

Details
Abstract
In this paper, a starting torque of a pressure balanced type vane motor is analysed and the calculated results are compared with experimental results. Bottom sides of vanes of the motor used in this work are always pushed radially by inlet pressure. Therefore the mechanical efficiency of the motor is less than 60% at start. Next, whole torque performances from start to maximum speed are investigated experimentally. And it becomes clear that the frictional torque of the motor increases with a decrease of rotational speed and it takes maximum value at start. The change of the frictional torque form start to maximum speed is continuous and its value at 0.01 rpm is almost equal to that at start.
Content from these authors
© The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top