Bulletin of JSME
Online ISSN : 1881-1426
Print ISSN : 0021-3764
Water Hammer in the Circulating Pipe Line with Pressure Vessels
Eiji KATOMinoru SUITAMasaaki KAWAMATAMasumi YUDA
Author information
JOURNAL FREE ACCESS

1984 Volume 27 Issue 228 Pages 1182-1187

Details
Abstract
Studies have been made to compare and discuss the analytical solutions obtained by the method of characteristics with the experimental results on the water hammer. The measurements have been carried out using a 1/6 scale model of the primary coolant system of the experimental fast breeder reactor "JOYO" belonging to the Power Reactor and Nuclear Fuel Development Corporation. The water hammer has been taken place at flow velocities 0.5 and 1.0 m/s, caused by closing slowly the flow control clap valve in the time ranges 4.5∼9.6 seconds and 4.6∼11.2 seconds respectively. Qualitative agreement was found between the analytical and experimental results. And the calculation gave the safety value at the peak pressure. Therefore the calculation models and idea used in this paper have sufficient practical value.
Content from these authors
© The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top