Bulletin of JSME
Online ISSN : 1881-1426
Print ISSN : 0021-3764
Dynamic Characteristics of a Bypass Type Flowmeter
Yutaka NISHIMURAYoshishige OHYAMA
Author information
JOURNAL FREE ACCESS

1986 Volume 29 Issue 247 Pages 99-105

Details
Abstract

Dynamic characteristics of a bypass type flowmeter in pulsating flow and in transient flow were studied analytically and experimentally. (1) Parameters which influence measurement errors of the mean flow rate of pulsating flow with the bypass type flowmeter were clarified. (2) Depending on the configuration of the bypass passage, there were cases where the measured value of mean flow rate was larger than the true value and where it was less; a suitable configuration of the bypass passage should be used, to obtain a value that is close to the true one. (3) Parameters which influence response of the flow in the byapss passage during accelerating or decelerating flow were clarified.

Content from these authors
© The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top