The Abstracts of ATEM : International Conference on Advanced Technology in Experimental Mechanics : Asian Conference on Experimental Mechanics
Online ISSN : 2424-2837
2003.2
Session ID : OS12W0017
Conference information
OS12W0017 Evaluation of sensitization and corrosive damage of the weldment for SUS316 steel
Eui Gyun NaSeung Ki KohHoon Kim
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
It was verified that anodic polarization method is suitable to evaluate the sensitization degree of the stainless steel at passive region. Heat treated weldment and parent metal is more sensitized compared with the weldment and parent metal. Specially, heat treated weldment at 730℃, 4 hr holding time and cooling in furnace is most sensitized. Unstable passive film for the heated treated weldment was formed because of the Cr depleted zone at passive region. In case of the parent metal, time to failure in synthetic seawater is longer than that in air. However, time to failure for the weldment and heat treated weldment in synthetic seawater is shorter than that in air. In case of the heat treated weldment, corrosive damage is the most greatest among other specimens.
Content from these authors
© 2003 The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top