JSME International Journal Series B Fluids and Thermal Engineering
Online ISSN : 1347-5371
Print ISSN : 1340-8054
ISSN-L : 1340-8054
PAPERS
System Outline and Operational Status of Karita Power Station New Unit 1 (PFBC)
Akihisa ASAIKazuhiro IZAKIYouichi EGAMIKouhei TSUJIShunji KUMAGAIYuuji NISHIJIMA
Author information
JOURNAL FREE ACCESS

2004 Volume 47 Issue 2 Pages 193-199

Details
Abstract
Karita Power Station New Unit 1, which started commercial operation on July 3, 2001, has adopted the new power generation system PFBC, Pressurized Fluidized Bed Combustion, a combined cycle generation system. The system boasts high thermal efficiency, excellent environmental characteristics and compact size. Output from the steam turbine generator and gas turbine generator is 290MW and 75MW, respectively, with total output adjusted to 360MW, making the unit the largest PFBC plant in the world. In October 2002, combustion tests were conducted using an anthracite coal from Yangquan; and in April 2003, a world record was achieved for continuous operation hours of a PFBC plant. This paper focuses on the outline and operation status of Karita New Unit 1.
Content from these authors
© 2004 by The Japan Society of Mechanical Engineers
Previous article Next article
feedback