Dryout in a Boiling Channel under Oscillatory Flow Condition
Hisashi UMEKAWAMamoru OZAWAAkira MIYAZAKIKaichiro MISHIMATakashi HIBIKI
Author information
JOURNAL FREE ACCESS

1996 Volume 39 Issue 2 Pages 412-418

Details
Abstract
Premature dryout due to flow oscillation is a very important factor in designing boiling systems. The flow oscillation depends, in general, on system size and/or configuration, and therefore the relationship between the premature dryout and the flow oscillation has not been fully understood so far. In this investigation, a CHF experiment in a forced flow boiling channel under the oscillatory flow condition has been conducted. Numerical simulation has also been conducted based on the lumped-parameter model of the boiling channel. The simulation well represents the transient behavior of the dryout under the oscillatory flow condition.
Content from these authors