Numerical Study on Variation of Feedback Methods in Ultrasonic-Measurement-Integrated Simulation of Blood Flow in the Aneurysmal Aorta
Kenichi FUNAMOTOToshiyuki HAYASEYoshifumi SAIJOTomoyuki YAMBE
Author information
JOURNAL FREE ACCESS

2006 Volume 49 Issue 1 Pages 144-155

Details
Abstract
The complicated relationships between hemodynamics and aneurysms have been investigated intensively. However, existing methodologies have inherent limitations in providing real blood flow fields. The authors have proposed Ultrasonic-Measurement-Integrated (UMI) simulation, in which the feedback signals lead to convergence of the calculated blood flow structure to the real one even with incorrect boundary/initial conditions. In UMI simulation, determination of the feedback law is substantially important, but detailed particulars remain to be accounted for. In this paper, first, the effects of density of feedback points and feedback domains are systematically investigated. Improvement of computational accuracy in the feedback domain is achieved even in low density of feedback points of 25%, and such improvement persists in the downstream region. Secondly, the most effective combination of feedback gains for momentum and pressure equations is investigated, confirming the validity of the simple condition to use the same value for the velocity and pressure gains.
Content from these authors
© 2006 by The Japan Society of Mechanical Engineers
Previous article Next article
feedback