The Proceedings of the Dynamics & Design Conference
Online ISSN : 2424-2993
2009
Session ID : 227
Conference information
227 Analysis of ground vibration and its isolation by using a dynamic damper due to a repeated impulsive force
Shozo KAWAMURASyu ITOHirofumi MINAMOTO
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
In this study, the simple method to isolate the ground vibration due to a construction machine, which is a rock drill, is proposed by using a dynamic damper. The ground is modelled by FEM and the external force is set as the repeated impact. The ground vibrations at some estimation points are calculated for various location of dynamic damper. As numerical results, the ground vibration is most suppressed when a dynamic damper is set near the vibration source and the dynamic damper increase the isolation effect of trench.
Content from these authors
© 2009 The Japan Society of Mechanical Engineers