The Proceedings of the Dynamics & Design Conference
Online ISSN : 2424-2993
2016
Session ID : 212
Conference information

A Study on Connected Control Mechanism for A Single Building Divided into Four Internally
Hiroyuki TAKAHASHIHiroyuki TOYODATakahiro TAKANOToru WATANABEKazuto SETO
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract

The connected control method (CCM) utilized reaction force between buildings as damping force by using connecting springs and dampers. The effectiveness of CCM has already been established in previous studies. In this paper, integrated connected control method (ICCM) with an experimental high-rise building split into four substructures is presented for a vibration control method to mitigate structural vibration by using internal damping force by CCM. To examine the effectiveness of ICCM, an experimental structure model split into four substructure is build and four dampers are introduced to realize experimental ICCM. Using this model, the effectiveness ICCM is investigated through computer simulations and experiments.

Content from these authors
© 2016 The Japan Society of Mechanical Engineers