Report of the experiment on the effect for the driving units of the fire extinguishing water that flows into the hoistway.
Takashi INAGAKIKoji NOMURAKatsunori HAKOZAKIAtsushi MASAOKAMotoo SHIMOAKISatoshi FUJITA
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract

In firefighting operation, the extinguishing water may flow into the hoistway. In case of the machine-roomless elevator is applied for the fire fighter's service elevator, the extinguishing water would splash to traction machines or control panels. Therefore, we carried out a full-size experiment of the elevator hoistway to obtain technical knowledge how the extinguishing water splashes in the hoistway. From the result of our experiment, we verify the installation position and its waterproof protection grade for traction machines or control panels.