The Proceedings of the Symposium on Environmental Engineering
Online ISSN : 2424-2969
2000.10
Conference information
Study for Active Control of Jet-Fan Noise
Masanori WATANABEYasushi TAKANOTadashi KOODUHidetoshi TERASAKAShiro ISE
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Pages 45-48

Details
Abstract
This paper describes reduction method of Jet-Fan noise using Active Noise Control (ANC) systems. The dominant frequency component of Jet-Fan noise is the blade passing frequency (BPF) of rotating fan blades. To reduce the BPF, we have used a multi channel ANC system using four error sensors and twelve speakers. Results show, (1) Coupling one error sensor and three speakers is effective. (2) The BPF component can be reduced by 9dB three-dimensionally at the optimal position of the error sensors.
Content from these authors
© 2000 The Japan Society of Mechanical Engineers
Previous article Next article
feedback