The Proceedings of the Symposium on Environmental Engineering
Online ISSN : 2424-2969
2002.12
Conference information
Demonstration Test Result of Advanced Combustion System
Kosaku OMORIKiyomitsu IKAWATomonori ASOJin AKIYAMATakatoshi TAMAMURAKatsutoshi YOKOYAMAToshiaki SATO
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Pages 296-299

Details
Abstract
We have conducted a demonstration test of a new-generation waste incineration plant embodying advanced combustion technology that reduces the amount of exhaust gas by means of combustion under low air ratio, and simultaneously controls NOx, CO and DXNs. At the air ratio of 1.3,the ignition loss was kept at the level of conventional furnaces whereas the amount of exhaust gas was reduced by 20% and NOx by 30%. The average CO concentration was below 1ppm while its peak was kept under 20ppm, and the total DXNs emission was cut down by 60%.