Investigation of collection efficiency and pressure drop depending on boss shape for axial flow cyclone dust collector with fixed guide vanes
Yasuyuki MatsukawaKathuyosi SaruyamaHiroaki WatanabeHideki AnzoAkira Ogawa
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Pages 366-369

Details
Abstract
A cyclone dust collector is very simple construction and it is easy to maintain and control. Therefore it is used widely in many industries. In this paper the collection efficiency depended on the feed particle concentration and the presser drop of pure gas flow ware investigated for the Potential Flow Type in axial flow cyclone dust collector with fixed guide vanes. The boss shape of potential flow type is calculated with complex potential flow functions. The feed particle was fly-ash of the mean size Xp50=5.59 (μ m). The feed particle concentrations ware Co (g/m3)=2.5 5.0 7.5 and 10.0.