301 Study for development of large capacity filtration system using immersion type MF membrane
Koji KASHIMADATsuyoshi NAKAYAMAManabu SASAGAWA
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
While the membrane filtration technology is installed into small-medium scale purification plants, its application to a large scale plant is also studied and incorporated. In this study, an experiment was performed to solve possible problems, using a high density immersion type hollow fiber MF membrane unit developed for large scale filtration plants. As a result, 1) experiment of the high density immersion membrane was performed and a stable operation result was obtained. 2) By using a filtration membrane for backwashing waste water, the system with the recovery rate of 99.9 to 99.95% was established. 3) In case study, estimated footprint of membrane process is less than half of conventional method but another 50% electricity is needed.