302 Continuous Operation of Boiler Emission Treatment Plant Combined with Nonthermal Plasma
Tomoyuki KUROKIHidekatsu FUJISHIMAKeiichi OTSUKATomohito ITOAtsumi TATSUMIMasaaki OKUBOToshiaki YAMAMOTOKeiichiro YOSHIDA
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
Continuous operation tests of the boiler emission treatment plant which consists of a commercial ozonizer for indirect NO oxidation and a Na_2SO_3 chemical scrubber are carried out for gas firing and heavy oil boilers. For gas firing boiler emission, the NO complete removal and the decrease in NO_x from 32 ppm to 3 ppm are achieved. This performance is maintained for 300 min by keeping -30 mV of oxidation-reduction potential (ORP) of circulating solution in the chemical scrubber. Concerning the treatment of heavy oil boiler emission, the decrease in NO_x from 90 ppm to less than 25 ppm is maintained for 250 min by keeping -30 mV of ORP. However, the unreacted NO of 15 ppm is detected at a scrubber outlet because the O_3 for NO oxidation is inadequate. By sufficient O_3 injection for NO oxidation, NO_x removal efficiency can be improved.