The Proceedings of the Symposium on Environmental Engineering
Online ISSN : 2424-2969
2016.26
Session ID : 309
Conference information

Development of a small sterilization device by controlling the air flow induced by plasma.
Hideto KamiyamaTomoki NakajimaShigeru FujimuraTakehiko Sato
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract

Plasma sterilization has a potential as an alternative method against conventional sterilization methods because it enables to operate at low temperature, low cost and high safety. In this study, we developed a small sterilization device to which plasma actuator is applied, and formed an air flow by generating plasma which can transport chemical species efficiently. Sterilization tests for two cases of air and water were performed. It took 2 min in the case of air and 15 min in the case of water. Reactive chemical species such as NOx are considered as the sterilization factors. The air flow generated by plasma was also enabled to enhance the effect on sterilization.

Content from these authors
© 2016 The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top