The Proceedings of the Fluids engineering conference
Online ISSN : 2424-2896
2013
Conference information
0802 Frequency response analysis of a tuned magnetic fluid column damper based on a linearized method
Kazuki IKARIToshiyuki OYAMADATatsuo SAWADA
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Pages _0802-01_-_0802-05_

Details
Abstract
In this paper, frequency response analysis of a tuned liquid column damper using magnetic fluid (MF-TLCD) based on a linearized method was presented. An MF-TLCD alters the natural frequency of the magnetic fluid column that forms the resident liquid inside the MF-TLCD by applying a magnetic field. The interaction equations of motion under a harmonic type of loading for SDOF damped structure and liquid surface motion in a MFTLCD were expressed. The damping term induced by liquid flows and the magnetic force term were linearized to derive analytical solutions. The analytical results were compared with experimental results.
Content from these authors
© 2013 The Japan Society of Mechanical Engineers
Previous article Next article
feedback