Abstract
Pressure Retarded Osmosis (PRO) is one of the power generation systems. The flow in a membrane module is simulated for PRO operation with parameters, flow rate of sea water, permeability coefficient, hollow fiber diameter, module length, and module diameter. When we investigated the relationship about flow rate of sea water, module length and module diameter, it was found that there is best condition about these.