The Proceedings of the Fluids engineering conference
Online ISSN : 2424-2896
2015
Session ID : 1006
Conference information
1006 Detection Limit Improvement of Unsteady PSP Measurement for Unsteady Aeroacoustic Flow Fields
Kazuyuki NAKAKITA
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
Unsteady PSP technique to detect small unsteady pressure fluctuation is required to minimize its noise level and improve detection limit. One approach to update a high-speed camera, which had larger sensitivity, was investigated its performance to decrease the unsteady PSP measurement system noise. Two types of system tests, which were an AA-PSP sample test and a wind tunnel test using NACA0012 model, was conducted. Larger sensitivity camera could reduce noise floor and its factor was from 3 to 6. Detection limit using a larger sensitivity camera was 20Pa2 for the 10,240 images AA-PSP sample test and 3Pa2 for the 46,592 images wind tunnel test.