Verification of Inclined Rate Effect in Inclined Settling Rectangular Tube
*Shin SATOHiroto HIRANO
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract

Solid-liquid two-phase flow was studied in an inclined settling rectangular tube. Three kinds of inclined settling rectangular tube was used this experiment where distance between inclined side plates is 53, 83 and 114 mm. The upward flow velocity and downward flow velocity were measured, and inclined rate effect in an inclined settling rectangular tube was studied experimentally. Moreover, the velocity ratio of each component was calculated. At the equipment of height 300mm, the optimum distance between inclined side plates was proved to be 83 mm.