Abstract
A supercritical CO2 gas turbine of 20MPa is suitable to couple with the Na-cooled fast reactor since Na - CO2 reaction is mild at the outlet temperature of 800K, the cycle thermal efficiency is relatively high and the size of CO2 gas turbine is very compact. In this gas turbine cycle, a compressor operates near the critical point. The property of CO2 and then the behavior of compressible flow near the critical point changes very sharply. So far, such a behavior is not examined sufficiently. Then, it is important to clarify compressible flow near the critical point. In this paper, the experimental data of the centrifugal supercritical CO2 compressor have been evaluated by CFD analyses using a computer code "CFX". In the analyses, real gas properties of CO2 were achieved by simulating density. The test compressor consists of three kinds of impeller. First, impeller A has 16 blades and the overall diameter is 110mm. Second, impeller B has 16 blades and the overall diameter is 76mm. Third, impeller C has 12 blades and the overall diameter is 56mm. Each impeller has each diffuser. So, CFD analysis was conducted for each impeller and each diffuser. The results were compared and evaluated for the three different impeller and diffuser sets. Main output of calculation is a value of the total pressure at diffuser outlet, which agreed very well with that of the experiment. Total and static pressure distributions, relative velocity distributions and temperature distributions surrounding impeller and diffuser were obtained. Adiabatic efficiency was also evaluated.