Abstract
This report shows fatigue evaluation of the circular notched plate under the interlaminar shear loading at elevated temperature. Test specimen made of SUS304 were prepared to added double notch to circular notched plate. FEM analysis of a specimen made to distribution of stress under the interlaminar shear loading. Fatigue tests were conducted, and compared with results of analysis. The results, stress distribution of the circular notched plate under the interlaminar shear loading shows unique compared to the plate under the interlaminar shear loading, or the circular notched plate under the tensile loading. And also consistent with experimental results.