Abstract
The film thickness and the concentration of thickener of grease which is composed by two phases has been measured in rolling point contacts by using FTIR microscope spectrometer under fully flooded condition because of the limit of film thickness by measuring range of FTIR. The results show that rolling speed, bulk concentration of thickener, and base oil viscosity influence film thickness and concentration of thickener.