Abstract
In this study, dependence of damping force of the particles damper on setting angle is investigated experimentally. The damping force is measured by using the load cell while the displacement is measured by the laser displacement sensor. It is shown that damping properties strongly depends on the setting angle of the damper due to the gravity.