The Proceedings of Mechanical Engineering Congress, Japan
Online ISSN : 2424-2667
ISSN-L : 2424-2667
2013
Session ID : J041041
Conference information
J041041 Time delay of the guided wave propagating in the elbow part of piping
Ryosuke NISHIGAWAHideo NISHINO
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
In this paper, axial locations of defect in elbow pipes were estimated by the T(0,1) mode guided waves. 50A Schedule 40 aluminum pipes with the JIS short-and long elbows and a 100A Schedule 40 aluminum pipe with the JIS long elbow were prepared and evaluated, respectively. The T(0,1) mode guided waves(30, 40 and 50 kHz) were generated and detected by the piezoelectric ring-shaped sensor system. In the straight regions of the elbow pipes, estimates were good agreement with the real locations of the artificial defects. In the regions beyond the elbows, the estimates were also fairly good agreement with the real locations if the calibrations of the time-delays during the propagations in elbow parts were carried out. The accuracies and errors of the estimations were discussed.
Content from these authors
© 2013 The Japan Society of Mechanical Engineers
Previous article Next article
feedback