The Proceedings of Mechanical Engineering Congress, Japan
Online ISSN : 2424-2667
ISSN-L : 2424-2667
2013
Session ID : S172016
Conference information
S172016 Thinning Damage Factor of UT measurement for FRP component degraded by Surface Reaction Form
Masahiro KUSANOTetsuya SAKAISaiko AOKIMasatoshi KUBOUCHI
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
Fiber Reinforced Plastics (FRPs) are used as pipe, tank and duct in chemical plant because they have corrosion resistance and strength. However, FRPs might degrade slowly over a few decades. Since FRP and the other organic materials have been used rather recently and there is not so much information of durability compared with metals. Furthermore, applicable non-destructive test (NDT) on FRP is not confirmed yet. Hence, it is important to apply a NDT method on FRP equipment used in chemical plant. In this report, Ultrasonic Test (UT) inspected the degraded FRP tank used in chemical plant and error of UT was evaluated as standard deviation. The results of SEM, EDS and FT-IR indicated that degradation of this tank was categorized as 'surface reaction type'. Moreover, 'Damage Factor' in case of FRP tanks was calculated by reference to API 581 and 'Inspection Effectiveness' of UT was proposed from Risk Based Inspection points of view.
Content from these authors
© 2013 The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top