The Proceedings of Mechanical Engineering Congress, Japan
Online ISSN : 2424-2667
ISSN-L : 2424-2667
[volume title in Japanese]
Session ID : F082002
Conference information

Clamp-on ultrasonic steam flowmeter using damping material with high temperature endurance
*Tomohito HAYASHIHiroshi SASAKIShuichi UMEZAWAKatsuhiko SUGITA
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract

For energy efficient operation of steam facilities, it is often required to measure a wide range of vapor flow rate. Clamp-on flowmeters are advantageous when it is necessary to measure vapor flow rates in various locations within one facility. On the other hand, ultrasonic flowmeters are well-known for their wide range of measurable gas flow rate. In the past, a clamp-on ultrasonic gas flow meter was developed, however there was a need for a damping material able to propagate ultrasonic wave through high temperature vapor pipe. The development of a clamp-on ultrasonic steam flowmeter with a high temperature endurance silicone rubber damping material is presented here. Silicone with high loss modulus has demonstrated good damping characteristic of ultrasonic wave. Using this newly developed flowmeter, 25A SGP 0.3 MPa steam flow can be measured up to 28m/s velocity.

Content from these authors
© 2017 The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top