Abstract
This paper describes a design of 600MW HTGR closed cycle helium gas turbine power plant. Selection of main parameters such as a capacity, rector outlet and inlet temepratures and pressure are explained. A horizontal gas turbine arrangement is adopted whose advantage is explained. By this design, a thermal cycle efficiency of 47.8% has been achieved.