The proceedings of the JSME annual meeting
Online ISSN : 2433-1325
2003.3
Conference information
Development of High Performance Steam Separator System (2) Performance test for Improved lower pressure losses separator
Yukitaka YAMAZAKITakahisa KONDOTadashi NARABAYASHIShinichi MOROOKAKoji NISHIDAToshihiko FUKUDAAkihiro SAKASHITAJun MIZUTANI
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Pages 163-164

Details
Abstract
In order to verify the two-phase flow simulation method, 1/2.22 scale test section was used for high-pressure two-phase flow test. The pressure characteristics and the separating performance of the improved swirler designed by two-phase simulation method are also verified by 1/2.22 scale model experiment. It is found that the improved swirler can decrease pressure losses by about 59 percent compared to the conventional swirler and it can almost keep the same discharged water rate as the conventional swirler. We confirmed that the separator system with the selected swirler can decrease pressure losses more than 20 percent compared to the total pressure losses of the conventional separator without decreasing the discharged water rate by 1/2.22 scale-model experiment.
Content from these authors
© 2003 The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top