The proceedings of the JSME annual meeting
Online ISSN : 2433-1325
2003.4
Conference information
Verification of Ultrasonic Anomaly Diagnosis of Ball Bearing Using CAE
Akitoshi TAKEUCHISatoshi TAMAIHiroshi ISHIMARUHisakazu MORIAkihisa KATOHidehiko SUETSUGUTatsuhiko TAKAHASHI
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Pages 209-210

Details
Abstract
The reflectivity of ultrasonic wave from contacting surface between ball bearing and housing changed, when the inner ring was damaged, and echo height ratio decreased. In order to investigate the cause of this result, stress of contacting surface was calculated by CAE with shifting the position where the ball contacted with the inner ring flaw. As the result, it was clarified that the stress between outer ring and housing decreased, when the ball contacted with the flaw part. Especially, the decreasing ratio of stress between two surfaces was remarkable when flaw contacted near the sound axis of probe. However, in the case of ball contacting with flaw in the position away from the sound axis, the stress on the sound axis was almost equal to the flawless bearing. It can be concluded that the decrease of echo height ratio H was caused by the contact between ball and flaw near the sound axis.
Content from these authors
© 2003 The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top