Characteristics of an Ammonia-Water Mixture Turbine System with Low Temperature Heat Source
Keisuke TAKESHITAKoji MORIMOTOYoshiharu AMANOTakumi HASHIZUME
Author information
CONFERENCE PROCEEDINGS RESTRICTED ACCESS

Details
Abstract

This paper presents an experimental investigation on effectiveness of the AWM (Ammonia-Water Mixture) turbine system to the lower temperature heat sources. The system features two subsystems: a distillation/condensation subsystem (DCSS) and a vapor generator subsystem (VGSS). The experimental result and calculation results show that DCSS functions when the heat source is higher than 100 [℃], and VGSS functions when the heat source is over than 180 [℃]. Since the main application of the AWM turbine system is the heat recovery and there are abundant 100-200 [℃] exhaust heats as unused heat sources, effectiveness of the system to the lower temperature heat source, especially from 100 to 200 [℃], is very important. The experiment was carried out with changing the back pressure of the steam turbine.

Content from these authors
© 2004 The Japan Society of Mechanical Engineers