The proceedings of the JSME annual meeting
Online ISSN : 2433-1325
2006.3
Session ID : 4343
Conference information
4343 Development of System Verification Plant for Advanced Humid Air Turbine
Shigeo HATAMIYAShinya MARUSHIMAHidefumi ARAKI
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
The Advanced Humid Air Turbine system improves the gas turbine thermal efficiency by using high-humidity air without needing a high firing temperature and pressure ratio. The following gas turbine elemental technologies concerning humidity air have been developed to realize the AHAT system: compressor, recuperator, turbine blade cooling, and combustor. A system verification plant that consists of a gas turbine generator (two-stage radial compressor with pressure ratio 8, two-stage axial turbine, single-can combustor), recuperator, humidification tower, water recovery system, and other components will be completed in a few months. The validation and performance test begin in October 2006. The expected performance is: rated output 3.6MW, efficiency 43% (LHV), and NO_x emissions less than 10ppm at 16% O2 from 50% to 100% load.
Content from these authors
© 2006 The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top