The proceedings of the JSME annual meeting
Online ISSN : 2433-1325
2010.3
Session ID : G0600-2-5
Conference information
G0600-2-5 Effects of axial angle on mixed convection in horizontal square duct with uniform wall temperature
Koji TORIYAMA
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
This paper describes the effect of axial angle on mixed convection in horizontal square duct with uniform wall temperature by the three-dimensional numerical analysis. The velocity fields and the pressure and temperature distributions obtained by SIMPLE method using non-dimensional governing equations. The QUICK scheme was applied to the convection term of momentum and energy equations. Numerical results show that the three-dimensional flow behavior was influenced by axial angles. The heat transfer behavior was discussed corresponding to the flow, and the heat transfer enhancement was different about 10% by axial angles.
Content from these authors
© 2010 The Japan Society of Mechanical Engineers