The Proceedings of the Materials and Mechanics Conference
Online ISSN : 2424-2845
2011
Session ID : OS0711
Conference information
OS0711 On Shear Mode Fatigue Crack Growth Test
Masahiro EndoAtsushi KusabaSaburo OkazakiKeiji YanaseShigeaki MoriyamaHisao Matsunaga
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
It is recognized that flaking-type failure due to contact fatigue is closely related to the growth of the shear-mode (Modes II and III) fatigue crack. In our research group, it is demonstrated that a shear mode fatigue crack can be reproduced for the cylindrical specimens by applying the cyclic torsion in the presence of the static axial compressive stress. However, a biaxial servo-hydraulic fatigue testing machine used is quite expensive to purchase and costly to maintain. Low testing speed (〜10 Hz) of the testing machine further aggravates the situation. As a result, study on shear mode fatigue crack growth is still in nascent stage. To overcome those difficulties, we have developed a high performance and cost-effective testing machine to reproduce the shear mode fatigue crack growth by improving the available resonance-type torsion fatigue testing machine. The primary advantage of using the resonance-type torsion fatigue testing machine is cost-efficiency. In addition, the testing speed can be effectively improved in comparison with that of a biaxial servo-hydraulic fatigue testing machine.
Content from these authors
© 2011 The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top