Host: The Japan Society of Mechanical Engineers
Name : [in Japanese]
Date : October 07, 2017 - October 09, 2017
Fully reversed tension-compression cyclic loading experiment is conducted for a copper single crystal micro-specimen with a single slip orientation under constant deformation amplitude control. Cyclic loading brings about nanoscale extrusion/intrusion on the specimen surface, which is not developed in monotonic loading. The size of extrusion/intrusion is much different from that of bulk counterpart. This indicates that micro-scale metallic materials possess a characteristic fatigue behavior.