The Proceedings of the Symposium on the Motion and Vibration Control
Online ISSN : 2424-3000
2010
Session ID : 1A13
Conference information
1A13 Reduction of Vibration of Structure using Oil Damper : Examination from Simulation Method
Shigeru AOKIKatsumi KURITAyuuki YOKOYAMA
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
Many houses were destroyed in destructive earthquakes in the world. Then, control of seismic response of house is important for protection from destruction. In this paper, two story houses are focused on and oil dampers of some shapes are proposed. Oil damper is connected to the ceiling of the first story and the foundation. The spherical damper, the rectangular parallelepiped damper and the cylindrical damper with silicon oil are proposed. The effectiveness of the dampers is examined experimentally. It is concluded that the peak of the frequency response function of the first vibration mode decreases and the damping ratio increases when the dampers are used. From simulation method using the analytical model, it is found that the maximum response decreases when the dampers are used.
Content from these authors
© 2010 The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top