Abstract
Study aims to monitor the AEs from the rust produced in stress corrosion cracking (SCC). AE monitoring during rust growth by salting on SCC surface of clad SUS304 and butt-weld 304 tube were attempted. AE frequency and amplitude changed significantly depending on the specimen and rust-forming environmental condition, however, AE can be used as SCC monitoring.