The Proceedings of the Symposium on Motion and Power Transmission
Online ISSN : 2424-306X
2013
Session ID : 3204
Conference information
3204 Evaluation of DLC Film Strength using Cyclic Plunge Load
Morimasa NAKAMURAShuji YOSHIOKASatoru HATTORIHioshi KITAGAKIIchiro MORIWAKI
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
The present paper illustrates evaluation of DLC (Diamond-like Carbon) film strength using cyclic plunge load. DLC film strength is generally evaluated using Rockwell hardness measurement, or scratch test. However, these evaluations may not be effective method for DLC film strength which is subjected to cyclic load. Therefore, cyclic plunge load test is proposed for strength evaluation. As a result, it was found that DLC film did not show failure by 27.5N plunge load (number of cycles 10^4) and 65.0N (number of cycles 10^3). And DLC film shows failure by 65.0N plunge load (number of cycles 10^4). In addition, failure points were thought to be inside near by surface of indentation.
Content from these authors
© 2013 The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top