The Proceedings of the National Symposium on Power and Energy Systems
Online ISSN : 2424-2950
2012.17
Session ID : C214
Conference information
C214 Visualization Test Using Piping Group Mock Up Specimen for Evaluation of Wastage Phenomena in Steam Generator for FBR
Keisuke KATOAtsuro YOSHIDAKunihiko ARAETadashi NARABAYASHIHiroyuki OHSHIMAAkikazu KURIHARA
Author information
Keywords: FBR, LDIE, SG, two phase flow
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
There is a need for quantitative evaluation of wastage phenomena in steam generator for FBR. We focused attention on liquid droplet impingement erosion (LDIE) in wastage phenomena and performed basic study with piping group mock up specimen for quantitative evaluation of LDIE. First, we did visualization test of high pressure and high speed jet into the water. Test section mock up the crack of heat exchanger tube and neighboring heat exchanger tubes. We did the test under the following test conditions. Upstream pressure is 0.3MPa, vapor temperature is 300K, crack width is 0.1mm, and crack length is 40mm. (crack diameter is 0.2mm) Second, we did pressure and temperature measurement test in the same test conditions as before. We evaluated jet behavior at test section by those two tests. In addition, we did two phase flow analysis of the jet with TRAC code.
Content from these authors
© 2012 The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top