The Proceedings of the National Symposium on Power and Energy Systems
Online ISSN : 2424-2950
2016.21
Session ID : A211
Conference information

Two-phase pressure drop for gas and non-Newtonian liquid flows through circular microchannel
Akimaro KAWAHARAAkifumi MORIWen Zhe LAWYukihiro YonemotoMohamed H. MANSOURMichio SADATOMI
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract

This study investigated pressure drop for gas and non-Newtonian liquid two-phase flows in a horizontal circular microchannel. The microchannel was a fused silica tube with 0.25 mm I.D. Polyacrylamide aqueous solutions with different mass concentration, which exhibit pseudo plastic behavior, were used as non-Newtonian liquid, while the nitrogen gas was used as the test gas. Pressure drop was measured with a calibrated differential pressure transducer. The pressure drop data have been compared with calculations by various correlations, usually used for prediction of the pressure drop in mini/micro channels as well as conventional sized channel. As the comparison results, the data have been correlated with separated flow model by using a newly developed equation of two-phase friction factor as well as homogenous flow model with an effective viscosity accounting for non-Newtonian effects. The Lockhart-Martinelli model also predicted well the present data if an appropriate C-value in two-phase friction multiplier was adopted.

Content from these authors
© 2016 The Japan Society of Mechanical Engineers
Previous article Next article
feedback