The Proceedings of the National Symposium on Power and Energy Systems
Online ISSN : 2424-2950
[volume title in Japanese]
Session ID : B134
Conference information

Steam and Non-condensable gas cooling method by falling liquid film
*Kei MASHIMOKoichi YOSHIMURAKatsuya YAMASHITAEiichi SAKAUEOsamu FURUYA
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract

Since non-condensable gas is contained in the steam at geothermal power plant, it is required for the purpose of simplifying a gas discharge system for plant efficiency improvement that emission gas should be made to fully cool and a volume flow should be made small. It is common to adopt how to cool the gas by direct contact for geothermal energy. We researched the cooling capability by the direct contact with the falling liquid film using structured packing. Experimental apparatus (Figure1) mainly consists of an evaporator, a cooling unit, and a vacuum pump. In the cooling section at the test equipment, Mixed gas(steam and air) and cooling water were floated by opposed flow : Mixed gas flows upward, and steam flows downward. Our conclusion in the experiment is that the cooling capability of falling liquid film has sufficient capability to cool mixed gas with high non-condensable gas density to cooling water temperture.

Content from these authors
© 2017 The Japan Society of Mechanical Engineers